Skip to content
Engineering Tools

Engineering Tools

Lapple d50 + Shepherd-Lapple ΔP Pre-sizing tool

Cyclone Separator Design Simulator

Geometry: Stairmand and Lapple ratio families. Calculation: Lapple cut diameter (d50), overall efficiency from a log-normal dust size distribution and Shepherd-Lapple pressure drop.

1. Gas and Operating Conditions

Am³/h

°C

m

Pa

Enter a negative value on the suction side (e.g. −2000 Pa).

2. Dust Data

kg/m³

True density of the solid; not bulk density and not concentration (g/m³).

g/Am³

A high dust load raises both efficiency and wear; this tool applies no load correction.

µm

From the mass-based distribution; 1 = single-size dust.

Diameters are physical (Stokes) diameters. Convert aerodynamic data (e.g. cascade impactor) with d_phys ≈ d_ae·√(1000/ρp) (ρp in kg/m³).

Combustible dust (wood, flour, coal, aluminium etc.): ATEX / NFPA 68 venting and isolation must be designed in from the start.

3. Cyclone Geometry

mm

Diameter suggestion (target inlet velocity 20 m/s)

Cyclone Performance Results

Cut diameter (d50)

— µm

Particle size collected with 50 % efficiency.

Efficiency

— %

Pressure drop (ΔP)

— Pa (≈ — mmH₂O)

Typical range 0.5–2.5 kPa.

Inlet velocity (Vi)

— m/s

—

Estimated outlet emission

— mg/Am³

Emission is in mg/Am³ at operating conditions, wet basis. Legal limits are in mg/Nm³, dry gas, reference O₂; convert before comparing.

Actual flow per body

— Am³/h

Actual total flow: — Am³/h

Warnings and notes

    Dimensions (per body)

    Body diameter Dc — mm
    Inlet height a — mm
    Inlet width b — mm
    Gas outlet (vortex finder) diameter De — mm
    Vortex finder length S — mm
    Cylinder height h — mm
    Cone height H−h — mm
    Overall height H — mm
    Dust outlet diameter B — mm

    Preliminary dimensions from the selected ratio family; not a fabrication drawing. (mm)

    Turn this estimate into a quote

    Your inputs and results are copied into the request form. Our engineers verify them with your process data.

    Request a quote

    Calculation Method & Formulas (Lapple / Shepherd-Lapple)

    1. Flow: the calculation uses the actual (operating) flow. A normal flow is converted with Qa = Qn·(T/273.15)·(101.325/P), where P is the absolute pressure (from site altitude and static pressure).
    2. Geometry: all dimensions are ratios of the body diameter Dc. Stairmand high efficiency: a=0.5·Dc, b=0.2·Dc, De=0.5·Dc, S=0.5·Dc, h=1.5·Dc, H=4·Dc, B=0.375·Dc; Lapple conventional: a=0.5·Dc, b=0.25·Dc, De=0.5·Dc, S=0.625·Dc, h=2·Dc, H=4·Dc, B=0.25·Dc; Stairmand high throughput: a=0.75·Dc, b=0.375·Dc, De=0.75·Dc, S=0.875·Dc, h=1.5·Dc, H=4·Dc, B=0.375·Dc. The Stairmand ratios are textbook values.
    3. Inlet velocity and diameter suggestion: Vi = Q / (N·a·b). The suggested diameter for a target Vi = 20 m/s is Dc = √(Q / (N·(a/Dc)·(b/Dc)·Vi)). If a single body exceeds 1.5 m, the number of parallel bodies N is increased.
    4. Cut diameter (Lapple): d50 = √( 9·μ·b / (2π·Ne·Vi·(ρp−ρg)) ), Ne = (1/a)·[h + (H−h)/2]. Ne is the effective number of turns the gas makes in the body: Stairmand high efficiency 5.5, Lapple conventional 6.0, Stairmand high throughput 3.67. μ is the temperature-dependent gas viscosity (Sutherland).
    5. Efficiency: grade efficiency η(dp) = 1 / (1 + (d50/dp)²). Overall efficiency follows from a log-normal mass distribution (MMD, σg = d84/d50) as η = Σ ηi·mi.
    6. Pressure drop (Shepherd-Lapple): ΔP = ½·ρg·Vi²·NH, NH = 16·a·b/De². NH is the number of inlet velocity heads: Stairmand high efficiency 6.4, Lapple conventional 8, Stairmand high throughput 8.

    Worked example (Lapple conventional): Q = 10,000 m³/h, Dc = 1.0 m, T = 20 °C, ρp = 2,700 kg/m³ → Vi ≈ 22.2 m/s, NH = 8 → ΔP ≈ 2.4 kPa, d50 ≈ 4.2 µm.

    Results are a preliminary sizing; the gas is taken as air. For high-temperature, abrasive, sticky or high-load applications the final design must be verified with process data.